EMRA STEEL
Get a quote ↗
Circular hollow sections — product reference photograph
Home / Products / Profiles / Circular hollow sections
EMRA Steel · Products

Circular hollow sections

Compare dimensions, wall thicknesses, grades and supply options.

Circular hollow sections

Circular hollow sections are specified by outside diameter, wall thickness, material grade and manufacturing route.

Circular hollow sections: Size and weight portfolio

Circular hollow sections
Size / formMass referenceGuide / enquiry
Ø 42.4 × 2 mmViewRequest1.990 kg/mView guide
Request quotation
Ø 42.4 × 3 mmViewRequest2.910 kg/mView guide
Request quotation
Ø 48.3 × 2 mmViewRequest2.280 kg/mView guide
Request quotation
Ø 48.3 × 3.2 mmViewRequest3.560 kg/mView guide
Request quotation
Ø 48.3 × 4 mmViewRequest4.370 kg/mView guide
Request quotation
Ø 60.3 × 2 mmViewRequest2.880 kg/mView guide
Request quotation
Ø 60.3 × 3.2 mmViewRequest4.510 kg/mView guide
Request quotation
Ø 60.3 × 4 mmViewRequest5.550 kg/mView guide
Request quotation
Ø 76.1 × 3 mmViewRequest5.410 kg/mView guide
Request quotation
Ø 76.1 × 4 mmViewRequest7.110 kg/mView guide
Request quotation
Ø 88.9 × 3 mmViewRequest6.360 kg/mView guide
Request quotation
Ø 88.9 × 4 mmViewRequest8.380 kg/mView guide
Request quotation
Ø 101.6 × 4 mmViewRequest9.630 kg/mView guide
Request quotation
Ø 114.3 × 4 mmViewRequest10.900 kg/mView guide
Request quotation
Ø 114.3 × 6 mmViewRequest16.000 kg/mView guide
Request quotation
Ø 139.7 × 4 mmViewRequest13.400 kg/mView guide
Request quotation
Ø 168.3 × 6 mmViewRequest24.000 kg/mView guide
Request quotation
Ø 219.1 × 6 mmViewRequest31.500 kg/mView guide
Request quotation

Geometric estimates exclude rolling tolerances, coatings and process losses; hollow and rolled-section references include their own section-table basis. Calculated bar weights use unrounded mass. Values are not measured shipment weights. Confirm length, grade, manufacturing route, packing and supply in the offer; the existing image illustrates the product family.

EMRA Steel supports sourcing enquiries for Circular hollow sections. Review product dimensions, grades, standards and inspection requirements before requesting a quotation. Confirm quantity, delivery destination and the required schedule with our sales team.

Get a quote ↗

Circular hollow sections Technical and buying guide

EMRA Steel

Circular hollow sections are specified by outside diameter, wall thickness, material grade and manufacturing route.

Read more

Standards and applicability

Keep EN 10219 cold-formed welded and EN 10210 hot-finished routes separate. Numeric S355J2H rows below are EN 10219 references for t ≤ 16 mm, not automatic EN 10210 or S355NH data. The tensile band changes below 3 mm. Elongation is reduced from 20% to 18% where D/t < 15 for CHS or (B+H)/(2t) < 12.5 for RHS/SHS; below 3 mm confirm gauge length and specimen width. The 27 J at −20°C reference requires the applicable impact-testing and subsize rules. Confirm grade, wall, corner geometry, weld inspection and certificate for the actual route.

Mechanical reference table

Mechanical reference table
Grade / materialScope / conditionRe / Rp0.2 (MPa)Rm (MPa)A min. (%)Impact reference
S355J2HEN 10219; t < 3 mm≥355510–68020 / 18*27 J / −20°C
S355J2HEN 10219; 3 ≤ t ≤ 16 mm≥355470–63020 / 18*27 J / −20°C

Chemical composition references

Chemical composition references
Grade / materialScope / conditionC (%)Mn (%)Si (%)P (%)S (%)Cr / CEV (%)
S355J2HEN 10219; t ≤ 16 mm≤0.22≤1.60≤0.55≤0.030≤0.030CEV ≤0.45

Selected percentages by mass and test values are reference requirements within the stated scope, not the actual heat analysis or a complete specification. A dash means no value is declared here, not zero. Compare the offered heat and test results with the applicable specification and inspection document. If EN 10204 type 3.1 is required, agree document availability, heat traceability and test scope before ordering.

Inspection and export enquiry

Send the exact product, size, full grade and standard edition, delivery condition, quantity, test requirements and named destination. Confirm cutting, coating, bundle or coil mass, protection, unloading and the Incoterms delivery point in the quotation. The destination guidance below supports port and inland comparisons; it does not confirm local stock or a fixed price.

Circular hollow sections Technical and buying guide

EMRA Steel supports sourcing enquiries for Circular hollow sections. Review product dimensions, grades, standards and inspection requirements before requesting a quotation. Confirm quantity, delivery destination and the required schedule with our sales team.

Circular hollow sections are specified by outside diameter, wall thickness, material grade and manufacturing route.

Specification and dimensions

Specify the following dimensions or analysis details for Circular hollow sections: Outside diameter × wall thickness × length for circular sections; width × height × wall thickness × length for rectangular sections.. The examples below are enquiry references, not a confirmed stock range.

Grades and applicable standards

For structural circular tubes, specify cold-formed welded EN 10219-1 / EN 10219-2 or hot-finished EN 10210-1 / EN 10210-2. State the full grade, for example S355J2H for an EN 10219 enquiry or S355NH for EN 10210, subject to confirmation. Reference weights below identify their geometry basis. Outside diameter is not the same as nominal pipe size DN. Water, gas or pressure service requires its own applicable pipe standard, testing and approval. Confirm coating, end preparation and inspection documents.

Applications and project requirements

For Circular hollow sections, share the intended production process or project specification. Required properties, processing condition, surface acceptance and dimensional tolerances should reflect the actual application. Supply selection should be reviewed against the technical requirements rather than based on dimensions alone.

Inspection and traceability

Agree heat or batch identification, chemical analysis, applicable tests and dimensional checks before ordering. Specify inspection documents, acceptance criteria and any independent inspection requirements.

Circular hollow sections Prices and quotation requirements

Ø 42.4 × 2 mm

Ø 42.4 × 2 mm: outside diameter 42.4 mm and nominal wall thickness 2 mm. Reference mass approximately 1.99 kg/m (EN 10219 reference geometry); calculated weights are 11.94 kg for 6 m and 23.88 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 42.4 × 2 mm

Ø 42.4 × 3 mm

Ø 42.4 × 3 mm: outside diameter 42.4 mm and nominal wall thickness 3 mm. Reference mass approximately 2.91 kg/m (EN 10219 reference geometry); calculated weights are 17.46 kg for 6 m and 34.92 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 42.4 × 3 mm

Ø 48.3 × 2 mm

Ø 48.3 × 2 mm: outside diameter 48.3 mm and nominal wall thickness 2 mm. Reference mass approximately 2.28 kg/m (EN 10219 reference geometry); calculated weights are 13.68 kg for 6 m and 27.36 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 48.3 × 2 mm

Ø 48.3 × 3.2 mm

Ø 48.3 × 3.2 mm: outside diameter 48.3 mm and nominal wall thickness 3.2 mm. Reference mass approximately 3.56 kg/m (EN 10210 reference geometry); calculated weights are 21.36 kg for 6 m and 42.72 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 48.3 × 3.2 mm

Ø 48.3 × 4 mm

Ø 48.3 × 4 mm: outside diameter 48.3 mm and nominal wall thickness 4 mm. Reference mass approximately 4.37 kg/m (EN 10219 reference geometry); calculated weights are 26.22 kg for 6 m and 52.44 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 48.3 × 4 mm

Ø 60.3 × 2 mm

Ø 60.3 × 2 mm: outside diameter 60.3 mm and nominal wall thickness 2 mm. Reference mass approximately 2.88 kg/m (EN 10219 reference geometry); calculated weights are 17.28 kg for 6 m and 34.56 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 60.3 × 2 mm

Ø 60.3 × 3.2 mm

Ø 60.3 × 3.2 mm: outside diameter 60.3 mm and nominal wall thickness 3.2 mm. Reference mass approximately 4.51 kg/m (EN 10210 reference geometry); calculated weights are 27.06 kg for 6 m and 54.12 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 60.3 × 3.2 mm

Ø 60.3 × 4 mm

Ø 60.3 × 4 mm: outside diameter 60.3 mm and nominal wall thickness 4 mm. Reference mass approximately 5.55 kg/m (EN 10219 reference geometry); calculated weights are 33.3 kg for 6 m and 66.6 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 60.3 × 4 mm

Ø 76.1 × 3 mm

Ø 76.1 × 3 mm: outside diameter 76.1 mm and nominal wall thickness 3 mm. Reference mass approximately 5.41 kg/m (EN 10219 reference geometry); calculated weights are 32.46 kg for 6 m and 64.92 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 76.1 × 3 mm

Ø 76.1 × 4 mm

Ø 76.1 × 4 mm: outside diameter 76.1 mm and nominal wall thickness 4 mm. Reference mass approximately 7.11 kg/m (EN 10219 reference geometry); calculated weights are 42.66 kg for 6 m and 85.32 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 76.1 × 4 mm

Ø 88.9 × 3 mm

Ø 88.9 × 3 mm: outside diameter 88.9 mm and nominal wall thickness 3 mm. Reference mass approximately 6.36 kg/m (EN 10219 reference geometry); calculated weights are 38.16 kg for 6 m and 76.32 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 88.9 × 3 mm

Ø 88.9 × 4 mm

Ø 88.9 × 4 mm: outside diameter 88.9 mm and nominal wall thickness 4 mm. Reference mass approximately 8.38 kg/m (EN 10219 reference geometry); calculated weights are 50.28 kg for 6 m and 100.56 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 88.9 × 4 mm

Ø 101.6 × 4 mm

Ø 101.6 × 4 mm: outside diameter 101.6 mm and nominal wall thickness 4 mm. Reference mass approximately 9.63 kg/m (EN 10219 reference geometry); calculated weights are 57.78 kg for 6 m and 115.56 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 101.6 × 4 mm

Ø 114.3 × 4 mm

Ø 114.3 × 4 mm: outside diameter 114.3 mm and nominal wall thickness 4 mm. Reference mass approximately 10.9 kg/m (EN 10219 reference geometry); calculated weights are 65.4 kg for 6 m and 130.8 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 114.3 × 4 mm

Ø 114.3 × 6 mm

Ø 114.3 × 6 mm: outside diameter 114.3 mm and nominal wall thickness 6 mm. Reference mass approximately 16 kg/m (EN 10219 reference geometry); calculated weights are 96 kg for 6 m and 192 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 114.3 × 6 mm

Ø 139.7 × 4 mm

Ø 139.7 × 4 mm: outside diameter 139.7 mm and nominal wall thickness 4 mm. Reference mass approximately 13.4 kg/m (EN 10219 reference geometry); calculated weights are 80.4 kg for 6 m and 160.8 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 139.7 × 4 mm

Ø 168.3 × 6 mm

Ø 168.3 × 6 mm: outside diameter 168.3 mm and nominal wall thickness 6 mm. Reference mass approximately 24 kg/m (EN 10219 reference geometry); calculated weights are 144 kg for 6 m and 288 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 168.3 × 6 mm

Ø 219.1 × 6 mm

Ø 219.1 × 6 mm: outside diameter 219.1 mm and nominal wall thickness 6 mm. Reference mass approximately 31.5 kg/m (EN 10219 reference geometry); calculated weights are 189 kg for 6 m and 378 kg for 12 m. Request 6 m, 12 m or agreed cut lengths, subject to confirmation. Actual weight depends on dimensional tolerances and the supplied section; confirm the mill table and weighing basis. Ø 219.1 × 6 mm

Quotation requirements

For a Circular tube quotation, state the grade, manufacturing route, full standard, length, quantity, surface finish and delivery destination. Compare matching dimensions and wall thickness; confirm whether pricing and invoicing use theoretical or actual weighed mass. Galvanizing, cutting and end preparation can affect the offer. Get a quote

Frequently asked questions

Does an example mean immediate availability?

No. Examples are enquiry references; stock and delivery must be confirmed for the complete specification.

Can a different grade or standard be substituted?

Only after the proposed material and the project requirements have been technically reviewed.

Choose the product specification first; destination and shipment details belong in the delivery enquiry. Destination enquiry guides

Grade enquiries for Circular hollow sections

Circular hollow sections S355J2H

For Circular hollow sections S355J2H, confirm the complete material standard and edition, chemical analysis, delivery condition and inspection certificate. Review the offered material against the intended processing or project requirements. The designation is an enquiry reference; availability and equivalence to other grades require confirmation.

Circular hollow sections S355NH

For Circular hollow sections S355NH, confirm the complete material standard and edition, chemical analysis, delivery condition and inspection certificate. Review the offered material against the intended processing or project requirements. The designation is an enquiry reference; availability and equivalence to other grades require confirmation.

Get a quote ↗
Request a steel quote ↗