Review Steel slab for the 250 × 2000 × 6000 mm specification. Check material grade, dimensions, inspection documents and delivery requirements before requesting a quotation.
Steel slab 250 × 2000 × 6000 mm: Quick reference
Steel slab 250 × 2000 × 6000 mm
Parameter
Value
Size / form
250 × 2000 × 6000 mm
Wall / product thickness
250 mm
Mass
23550.000 kg
Dimensional / material references
Agreed in the order
Grade / material
Agreed in the order
Geometric estimates exclude rolling tolerances, coatings and process losses; hollow and rolled-section references include their own section-table basis. Calculated bar weights use unrounded mass. Values are not measured shipment weights. Confirm length, grade, manufacturing route, packing and supply in the offer; the existing image illustrates the product family.
Reference dimensions: 250 × 2000 × 6000 mm. At a nominal steel density of 7850 kg/m³, calculated mass is approximately 23550 kg per piece. Actual weighing, dimensional tolerances, grade and inspection requirements must be agreed before ordering. 250 × 2000 × 6000 mm
Steel slab 250 × 2000 × 6000 mm Technical and buying guide
EMRA Steel
Review Steel slab for the 250 × 2000 × 6000 mm specification. Check material grade, dimensions, inspection documents and delivery requirements before requesting a quotation.Read more
Standards and applicability
Specify the cast cross-section and cut length, full heat chemistry, deoxidation, surface acceptance, internal soundness and downstream rolling route. Finished EN 10025 mechanical values cannot certify an unrolled billet or slab. For 3SP/5SP requests, provide the complete GOST or other agreed specification and edition; no universal numerical chemistry is assigned from a short commercial name.
Analysis and acceptance matrix
Analysis and acceptance matrix
Analysis item
Unit
Acceptance limit
C
%
Agreed in the order
Mn
%
Agreed in the order
Si
%
Agreed in the order
P
%
Agreed in the order
S
%
Agreed in the order
Al
%
Agreed in the order
Nb
%
Agreed in the order
V
%
Agreed in the order
Ti
%
Agreed in the order
Selected percentages by mass and test values are reference requirements within the stated scope, not the actual heat analysis or a complete specification. A dash means no value is declared here, not zero. Compare the offered heat and test results with the applicable specification and inspection document. If EN 10204 type 3.1 is required, agree document availability, heat traceability and test scope before ordering.
Inspection and export enquiry
Send the exact product, size, full grade and standard edition, delivery condition, quantity, test requirements and named destination. Confirm cutting, coating, bundle or coil mass, protection, unloading and the Incoterms delivery point in the quotation. The destination guidance below supports port and inland comparisons; it does not confirm local stock or a fixed price.
Chemistry references and commercial grades
3SP and 5SP · GOST 380-2005 ladle analysis
3SP and 5SP refer here to fully killed Ст3сп and Ст5сп. These chemistry references support billet/slab enquiries; casting quality, residual elements, steelmaking-route exceptions and the downstream product standard remain separate order requirements. Finished rolled-steel mechanical properties do not certify an as-cast billet or slab.
3SP and 5SP · GOST 380-2005 ladle analysis
Grade / commercial type
C (%)
Mn (%)
Si (%)
P (%)
S (%)
3SP / Ст3сп
0.14–0.22
0.40–0.65
0.15–0.30
≤0.040
≤0.050
5SP / Ст5сп
0.28–0.37
0.50–0.80
0.15–0.30
≤0.040
≤0.050
Reference values are not shipment analysis or an inventory promise. Agree the complete specification, sampling basis, test methods and acceptance limits before ordering; confirm actual results on the heat/lot certificate. A dash means no numeric limit is stated in this selected reference, not zero.
Requested minimum manganese: 0.50% and 0.60%
Mn +0.50 and Mn +0.60 mean Mn ≥0.50% and Mn ≥0.60%. The table intersects each buyer minimum with the grade range. They are optional purchase limits, not new standard grade names. St52-3 has a maximum Mn limit in the reference below; a minimum of 0.50% or 0.60% requires separate mill agreement.
Requested minimum manganese: 0.50% and 0.60%
Grade / commercial type
Buyer requirement
Compatible Mn range (%)
3SP
Mn ≥0.50%
0.50–0.65
3SP
Mn ≥0.60%
0.60–0.65
5SP
Mn ≥0.50%
0.50–0.80
5SP
Mn ≥0.60%
0.60–0.80
Reference values are not shipment analysis or an inventory promise. Agree the complete specification, sampling basis, test methods and acceptance limits before ordering; confirm actual results on the heat/lot certificate. A dash means no numeric limit is stated in this selected reference, not zero.
St37, St44 and St52 · historical DIN 17100 reference
Ladle-analysis reference for St37-2, St44-2 and St52-3 at t ≤16 mm only. Bare St37/St44/St52 names need a suffix, edition and delivery condition. Other thicknesses and product analysis have different rules. These legacy grades are not automatically equivalent to EN grades or interchangeable with CK45/CK60. For semi-finished feedstock, agree chemistry and downstream qualification separately.
St37, St44 and St52 · historical DIN 17100 reference
Grade / commercial type
C (%)
Mn (%)
Si (%)
P (%)
S (%)
St37-2 / 1.0037
≤0.17
—
—
≤0.050
≤0.050
St44-2 / 1.0044
≤0.21
—
—
≤0.050
≤0.050
St52-3 / 1.0570
≤0.20
≤1.60
≤0.55
≤0.040
≤0.040
Reference values are not shipment analysis or an inventory promise. Agree the complete specification, sampling basis, test methods and acceptance limits before ordering; confirm actual results on the heat/lot certificate. A dash means no numeric limit is stated in this selected reference, not zero.
Size specifications: Steel slab 250 × 2000 × 6000 mm
Reference dimensions: 250 × 2000 × 6000 mm. At a nominal steel density of 7850 kg/m³, calculated mass is approximately 23550 kg per piece. Actual weighing, dimensional tolerances, grade and inspection requirements must be agreed before ordering. 250 × 2000 × 6000 mm
Choosing this specification
For 250 × 2000 × 6000 mm, agree the dimension order and whether the material is supplied as coil or cut lengths. Check usable width, cutting layout and flatness before comparing yield; nominal geometry does not include trimming or process losses. At nominal geometry and 7850 kg/m³ steel density, the reference is 23550.000 kg per piece. This calculation excludes tolerances, coatings, corner radii and process losses; it is not certified shipping weight or a load rating. Compared with 250 × 1500 × 6000 mm, the nominal geometric reference is 33.3% higher on the same basis. This comparison supports quantity planning; it does not establish interchangeability.
Grades, standards and inspection requirements for this product: Steel slab
Buying Steel slab 250 × 2000 × 6000 mm and requesting a price
The price for Steel slab 250 × 2000 × 6000 mm depends on the material specification, quantity, production or processing requirements, inspection, packing, freight and delivery schedule. Compare offers on the same technical specification and delivery basis; confirm availability and quotation validity before ordering.
For buying and price enquiries for Steel slab 250 × 2000 × 6000 mm, specify your delivery destination: Georgia (including Tbilisi), Turkey (including Ankara and Istanbul), the United Arab Emirates (UAE, including Dubai), Kuwait, Oman or Qatar. Send the required quantity, grade or chemical analysis, dimensions and inspection scope. Freight, delivery terms and shipment timing affect the quotation; supply options and destination documentation require confirmation before an order is agreed.
Preparing an enquiry for Steel slab 250 × 2000 × 6000 mm
Include Steel slab 250 × 2000 × 6000 mm, the required grade and complete standard designation, order quantity, length or coil limits where applicable, inspection documents and the exact delivery destination. Confirm traceability, packing, commercial terms and the shipment schedule with EMRA Steel.
Choose the product specification first; destination and shipment details belong in the delivery enquiry. Destination enquiry guides
Specification enquiries for Steel slab 250 × 2000 × 6000 mm
Steel slab 250 × 2000 × 6000 mm Chemical analysis
For Steel slab 250 × 2000 × 6000 mm Chemical analysis, define the applicable specification, acceptance limits, sampling and inspection documents. Include quantity and delivery destination so EMRA Steel can review the technical requirements and quotation basis.